New Mini Thermometer - Indoor Thermometer

Thermometer is the general name of the temperature measuring instrument, which is used frequently by us. It can measure the temperature anywhere to cope with the problems caused by temperature rise. The indoor Neo-Mini temperature/humidity sensor HTY70x3 series uses Pt100 platinum thermal resistance (IEC60751 or JIS C1604A grade) in the temperature measuring element, and uses a polymer capacitive humidity sensor in the humidity measuring element (we developed High-accuracy, high-reliability sensor made of FP3TM manufactured. Due to its wide measurement range and high stability, it can be used in a variety of indoor applications including general building air conditioning. There is also a separate temperature sensor and a separate humidity sensor.

Features 1) It can perform wide temperature and high accuracy measurement of temperature and humidity.

2) It has excellent long-term stability.

3) Has excellent environmental adaptability.

4) It has excellent response characteristics and repeatability.

5) Small size (ultra thin) and light weight.

The installation conditions 1) should be installed in a location that reflects the average room temperature and humidity and is about 1.5m above the ground.

2) Do not install near the OA equipment where heat builds up.

3) It should be avoided where it may be affected by pore air, downward ventilation, cold wind from water pipes or pipes, solar radiant heat, etc.

4) Do not allow it to be affected by ventilation from the wall conduit.

5) It should be installed in a place without vibration.

6) Avoid installation where there may be water droplets.

7) When selecting the installation site, consideration should be given to avoid condensation on the body.

Separate installation of Neo-Mini sensors 1) Use a flat painted lid or coated lid for wall mounting.

2) Insert a hex wrench with a tooth tip size of 1.5 mm into the long hole in the upper part of the Neo-Mini sensor, rotate the fastening screw clockwise, loosen the cover assembly, and decompose the Neo sensor into a cover assembly, printed circuit board assembly and Bracket assembly.

3) Mount the coated lid on the bracket assembly.

4) Make the wiring of the printed circuit board.

5) Insert the lower part of the printed circuit board into the slot of the spring part under the bracket assembly, press the printed circuit board assembly down, and insert the upper part into the upper slot of the bracket assembly.

6) While pressing the protrusion below the lid assembly from the bottom up, insert it into the spring portion under the bracket assembly, and then close the lid assembly.

7) Insert a hex wrench with a tooth tip size of 1.5 mm into the long hole in the upper part of the cap assembly, and turn the captive screw counterclockwise to fix the cap assembly.

air cooled unit

Refrigeration Compressor,Small Refrigeration Units,Trailer Refrigeration Unit

Boyang Compressor Co.,LTD , http://www.bycompressor.com